| |
|
Sweep-Up
Spray Alkyd Flat M51
|
|
MSDS |
Technical
Data Sheet |
Product
Information
This fast dry product is designed to provide
superior hiding for one coat work. Retains its
whiteness in presence of industrial fumes. The dry
fall qualities of this product cause the overspray
to settle as a dry powder in approximately 10 feet
of fall depending on air movement, temperature,
& humidity. Greatly reduces clean up costs.
May be applied on virtually any interior wall or
ceiling. Requires minimal surface preparation.
Clean up tools immediately after use with VM&P
naphtha or Xylol.
Recommended
Uses
Protects Interior industrial ceilings or walls.
Performs well where a high hiding less expensive
coating is needed. For production or work areas
where wet overspray could not be tolerated and
industrial areas exposed to welding or production
dust.
Colors:
M51-01 White
|
|
| Technical
Data |
White |
| Generic
Type |
Modified
Alkyd |
| Pigment
Type |
Titanium
Dioxide
|
| Volume
Solids |
48% |
| Spread
Rate per Gal. |
310
Sq.Ft. |
Film
Thickness
- Wet
- Dry |
5.2
mils
2.5 mils |
Dry
Time
- To Touch
- Recoat |
30
Minutes
1 hour |
| Dry
Heat Resistance |
250°
F |
| Viscosity |
80
± 5 KU |
| Flash
Point (Seta) |
75°
F |
| 60°
Specular Gloss |
0-10% |
| Clean
Up With |
M97 |
| Mixing
Ratio |
N/A |
| Induction
Time |
N/A |
| Pot
Life @ 70° F |
N/A |
|
| |
|
|
Sweep-Up
Spray Alkyd Eggshell M52
|
|
MSDS |
Technical
Data Sheet |
Product
Information
This fast dry product is designed to provide
superior hiding for one coat work. Retains its
whiteness in presence of industrial fumes. The dry
fall qualities of this product cause the overspray
to settle as a dry powder in approximately 10 feet
of fall depending on air movement, temperature,
and humidity. Greatly reduces clean up costs. May
be applied on virtually any interior wall or
ceiling. Requires minimal surface preparation.
Clean up tools immediately after use with VM&P
naphtha or Xylol.
Recommended
Uses
Protects interior industrial ceilings or walls.
Performs well where a high hiding, less expensive
coating is needed. For use over production or work
areas where wet overspray could not be tolerated
or areas exposed to welding or production dust.
Colors:
White
|
|
| Technical
Data |
White |
| Generic
Type |
Modified
Alkyd |
| Pigment
Type |
Titanium
Dioxide |
| Volume
Solids |
50% |
| Spread
Rate per Gal. |
400
Sq.Ft. |
Film
Thickness
- Wet
- Dry |
4.0
mils
2.5 mils |
Dry
Time
- To Touch
- Recoat |
30
Minutes
1 hour |
| Dry
Heat Resistance |
200°
F |
| Viscosity |
90
± 5 KU |
| Flash
Point (Seta) |
75°
F |
| 60°
Specular Gloss |
10-20% |
| Clean
Up With |
M97 |
| Mixing
Ratio |
N/A |
| Induction
Time |
N/A |
| Pot
Life @ 70° F |
N/A |
|
| |
|
|
Sweep-Up
Spray Latex Flat M53
|
|
MSDS |
Technical
Data Sheet |
Product
Information
This fast dry product is designed to provide
superior hiding for one coat work. Retains its
whiteness in presence of industrial fumes. The dry
fall qualities of this product cause the overspray
to settle as a dry powder in approximately 10 feet
of fall depending on air movement, temperature,
and humidity. Greatly reduces clean up costs. May
be applied on virtually any interior wall or
ceiling. Requires minimal surface preparation.
Clean up tools immediately after use with clean
water.
Recommended
Uses
Protects interior industrial ceilings or walls.
Performs well where a high hiding, less expensive
coating is needed. For use over production or work
areas where wet overspray could not be tolerated
or areas exposed to welding or production dust.
Colors:
M53-01 White
|
|
| Technical
Data |
White |
| Generic
Type |
Acrylic
Latex |
| Pigment
Type |
Titanium
Dioxide |
| Volume
Solids |
40% |
| Spread
Rate per Gal. |
320
Sq.Ft. |
Film
Thickness
- Wet
- Dry |
5.0
mils
2.0 mils |
Dry
Time
- To Touch
- Recoat |
30
Minutes
1 hour |
| Dry
Heat Resistance |
160°
F |
| Viscosity |
85
± 5 KU |
| Flash
Point (Seta) |
None |
| 60°
Specular Gloss |
0-10% |
| Clean
Up With |
Clean
Water |
| Mixing
Ratio |
N/A |
| Induction
Time |
N/A |
| Pot
Life @ 70° F |
N/A |
|
| |
|
|
Safety
& Zone Marking Alkyd M56
|
|
MSDS |
Technical
Data Sheet |
Product
Information
This fast dry alkyd coating is designed for
marking traffic lanes on streets, highways,
parking lots, airports, warehouses, shopping
centers. For designating parking spaces and other
vehicular or foot traffic control markings,
traffic beads may be utilized with this coating to
provide reflective marking, If beads are to be
used they should be dropped into the wet paint
immediately after application at a rate of 6
pounds per gallon of paint. This coating may be
applied to concrete or asphalt surfaces interior
or exterior.
Recommended
Uses
Coating asphalt or concrete surfaces, interior or
exterior, traffic lanes, streets & highways,
parking lots, parking spaces, crosswalks, fire
lanes, vehicular and floor traffic control
markings, "No Parking" areas, airports,
manufacturing plants, shopping centers, schools,
hospitals, warehouses.
Not for use as an
anti-slip coating on invalid ramps or sidewalks
without the addition of an anti-slip aggregate,.
Do not apply to extremely hot surfaces or when the
surface and air temperatures are below 50 F. Allow
newly applied asphalt seal coats to dry at least 4
days before application.
Colors:
M56-01 White
M56-10 Yellow
|
|
| Technical
Data |
White |
| Generic
Type |
Modified
Alkyd |
| Pigment
Type |
Titanium
Dioxide and Calcium Carbonate |
| Volume
Solids |
55% |
| Spread
Rate per Gal. |
3"
line: 440 feet
|
Film
Thickness
- Wet
- Dry |
14.5
mils
8.0 mils |
Dry
Time
- To Touch
- Recoat |
15
Minutes
|
| Dry
Heat Resistance |
200°
F |
| Viscosity |
80
± 5 KU |
| Flash
Point (Seta) |
None |
| 60°
Specular Gloss |
10-20% |
| Clean
Up With |
VM&P
Naphtha |
| Mixing
Ratio |
N/A |
| Induction
Time |
N/A |
| Pot
Life @ 70° F |
N/A |
|
| |
|
|
Safety
& Zone Marking Latex M58
|
| MSDS |
Technical
Data Sheet |
Product
Information
This fast dry latex coating is designed for
marking traffic lanes on streets, highways,
parking lots, airports, warehouses, shopping
centers. For designating parking spaces and other
vehicular or foot traffic control markings.
Traffic beads may be utilized with this coating to
provide reflective marking, If beads are to be
used they should be dropped into the wet paint
immediately after application at a rate of 6
pounds per gallon of paint. This coating may be
applied to concrete or asphalt surfaces interior
or exterior.
Recommended
Uses
Coating asphalt or concrete surfaces, interior or
exterior, traffic lanes, streets & highways,
parking lots, parking spaces, crosswalks, fire
lanes, vehicular and floor traffic control
markings, "No Parking" areas, airports,
manufacturing plants, shopping centers, schools,
hospitals, warehouses.
Not for use as an
anti-slip coating on invalid ramps or sidewalks
without the addition of an anti-slip aggregate,.
Do not apply to extremely hot surfaces or when the
surface and air temperatures are below 50° F.
Allow newly applied asphalt seal coats to dry at
least 4 days before application.
Colors:
M58-01 White
M58-10 Yellow
M58-20 Red
M58-30 Blue
M58-80 Black
|
|
| Technical
Data |
White |
| Generic
Type |
Acrylic
Latex |
| Pigment
Type |
Titanium
Dioxide |
| Volume
Solids |
58% |
| Spread
Rate per Gal. |
3"
line: 650 feet
|
Film
Thickness
- Wet
- Dry |
10.3
mils
6.0 mils |
Dry
Time
- To Touch
- Recoat |
30
Minutes
|
| Dry
Heat Resistance |
160°
F |
| Viscosity |
95
± 5 KU |
| Flash
Point (Seta) |
None |
| 60°
Specular Gloss |
10-20% |
| Clean
Up With |
Clean
Water |
| Mixing
Ratio |
N/A |
| Induction
Time |
N/A |
| Pot
Life @ 70° F |
N/A |
|
|
|
|